How to migrate removed Attributes from iCD 2024 to iCD 2025

The structure of the Building Model Attributes within iCD has been updated to deliver a more coherent and logical workflow to users in terms of setting models up and the inputs required. This update provides a more transparent link between the attribute values and the simulation results that come from the Apache engine so that a user can more readily identify the impact of the choices that they make when modelling the building.

The Query Tool, through which the building attributes are accessed, has also been restructured and updated to improve the user experience and make the editing of building models much easier.

To transfer attributes from 2024 to 2025 please follow the steps below:

On the old 2024 version’s toolbar click Extensions>IES iCD>Import/Export>Export CSV…

On the below pop up select Filter selected objects only, All buildings and Show. The buildings should be highlighted green as below.

From here you can select the attributes you want to export from the list on the right. In this example we’ll just select them all by clicking All. You will need to keep IESVE MP Object ID ticked under the attribute list as this will be used to match building IDs from 2024 to 2025 versions. Then click Export.

You be asked to save this file as per the below.

Once you’ve saved this in your chosen file path, you want to save and close your Sketchup model and install the new version of iCD 2025.

Once the installation is complete, open your model and now you need to create another CSV export similar to before for the iCD 2025 version. Steps below:

Extensions>IES iCD>Import/Export>Export CSV…

We have again selected All for the attributes to export.

Any old attributes you want transferred to your new model you will need to copy the column from your 2024 CSV into the last column on your 2025 CSV (this will add the removed attribute from 2024 to 2025 attributes as a custom attribute when you come to import). In the example below we’ve copied the now removed “Address # / street” attribute into the 2025 CSV.

Once you’re happy with your new 2025 CSV you can click the CSV import option below and follow the instructions.

Browse to your 2025 CSV:

Select IESVE MP Object ID for both dropdowns and click Next:

All rows should match as below, click Next:

The old address attribute “Address # / street” is now picked up as a custom attribute in step 4:

Click Import and your building data is now transferred to iCD 2025.

Additional Notes

The following attributes in the existing 2024 version of iCD have been impacted by this update, with some information and context included:

Name

Upgrade note

General

Roof overlap

User can define extra local shade to model the Roof overlap

HVAC service

Fuel Type (heating & hot water)

This attribute was changed to Heating fuel type (only). DHW has its own fuel type now.

ICL settings

Infiltration

"Infiltration max flow" renamed "Infiltration" to define the infiltration (Value in ac/h)

Heating/hot water generator efficiency

Attribute removed. Replaced by "Heating Source" and/or "Seasonal efficiency/CoP (Heating)"

Cooling generator efficiency

Attribute removed. Replaced by "Cooling Source" and/or "Seasonal EER (Cooling)"

Ventilation type

Removed. All ventilation power is now defined either via "Auxiliary max power consumption" or "Specific Fan power"

Hours of use

Modelled by different profile attributes that are now available

ICL intervention

Boiler plant improvements

No longer available

Chiller plant improvements

No longer available

Ventilation

Removed. Now indicated via attribute "Ventiliation Heat Recovery Effectiveness"

Distribution pipes insulation

Removed. Now modelled separately with "Delivery efficiency" attributes for heating, cooling and DHW.

Roof insulation

This dropdown attribute was removed. Now relying solely on Roof U-value

Loft insulation

This dropdown attribute was removed. Now relying solely on Ceiling U-value

Exposed floor insulation

This dropdown attribute was removed. Now relying solely on Ground floor U-value

External wall inner insulation

This dropdown attribute was removed. Now relying solely on Wall U-value

External wall outer insulation

This dropdown attribute was removed. Now relying solely on Roof U-value

Fabric opaque doors

Attribute removed.

Distribution systems insulation

Can be modelled with DHW delivery efficiency to some extent.

Heat pump (heating)

Attribute removed. Can be replaced by "Heating Source" and/or "Seasonal efficiency/CoP (Heating)"

Heat pump (cooling)

Attribute removed. Can be replaced by "Cooling Source" and/or "Seasonal EER (Cooling)"

Details (optional)

Vacancy rate

Attribute removed. Data should be moved to Custom attribute.

Rent

Attribute removed. Data should be moved to Custom attribute.

Condition

Attribute removed. Data should be moved to Custom attribute.

Ownership

Attribute removed. Data should be moved to Custom attribute.

Building id

Attribute removed. Data should be moved to Custom attribute.

Owner/occupier

Attribute removed. Data should be moved to Custom attribute.

Address # / street

Attribute removed. Data should be moved to Custom attribute.

Address district

Attribute removed. Data should be moved to Custom attribute.

Address town

Attribute removed. Data should be moved to Custom attribute.

Address region

Attribute removed. Data should be moved to Custom attribute.

Country

Attribute removed. Data should be moved to Custom attribute.

ZIP code

Attribute removed. Data should be moved to Custom attribute.

Has real data

Attribute removed. Data should be moved to Custom attribute.

Underlying land use

Attribute removed. Data should be moved to Custom attribute.

Flood plain / risk

Attribute removed. Data should be moved to Custom attribute.

Total investment cost

Attribute removed. Data should be moved to Custom attribute.

Advanced - System

Power factor - general

Attribute removed. Can no longer be modelled