Either:

1. An opening type that is referenced in the project has been renamed with the: "Update with description flag" on and this in turn has updated the ID.
2. The opening type has been deleted from the system.

Either way the system cannot now find this Opening Type. 

We need to add another opening type to the list with the expected Reference ID.
Important: Do not Save project until steps 1-4 are complete.

1. Record the missing reference ID (eg: XTRN0000)
2. Add a new opening type to the project
3. Set Description to be missing ID (eg: XTRN0000) * Ensure Update with description flag is checked.
4. Add some identifying text (eg - remember to replace!).
5. Save the project - this has added the missing opening type back in to the project and it should be selectable.